As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOOR APPEARED TO BE ARMED AFTER DOOR WAS OPENED. WHEN F/O OPENED LT ENTRY DOOR THE SLIDE WAS CAUGHT ON GIRT BAR AREA AND SLIDE FELL OUT. SLIDE DID NOT INFLATE F/O THOUGHT DOOR WAS UNARMED. FOUND L1 DOOR ASSIST BOTTLE DISCHARGED & DOOR WAS ARMED. R & R LEFT ENTRY DOOR EMERGENCY POWER RESERVOIR SECURED, IAW MM 52-11-30-4. OK FOR SERVICE.