What was found
RT ENGINE STARTED SURGING. EPR N1 EGT SURGED THEN RETURNED TO MATCH LT ENGINE. REPEATED AGAIN AND THEN A THIRD TIME. RT ENGINE N2 AND F/F STEADY DURING SURGING QRH COMPLIED WITH. A/T OFF AND REDUCED THRUST TO STABILIZED ENGINE. DESCENDED AND WITH NO FURTHER SURGING FROM RT ENGINE. NO AUDIBLE STALL HEARD. NO AUTO EVENTS LOGGED IN EPCS, NO ENGINE EXCEEDENCE, NO STATUS OR MX MESSAGES DISPLAYED ON EICAS. INSPECTED ENGINE, FAN MOVED FREELY, NO METAL DEBRIS FOUND IN EXHAUST SECTION, INLET AND FAN SHOW NO SIGNS OF FOD. R & R NR 2 ENGINE EEC IAW MM 71-00-00-5. ALL PARAMETERS NORMAL.