What was found
MAIN DECK CARGO AFT RT FLOORBOARD 252VF HAS TWO CRACKS 8 INCHES LONG AT CLEVIS CUTOUTS. FABRICATED, AND INSTALLED NEW FLOORBOARD IAW AMM 53-10-25-04-02 AND IAW DWG SRZ-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO AFT RT FLOORBOARD 252VF HAS TWO CRACKS 8 INCHES LONG AT CLEVIS CUTOUTS. FABRICATED, AND INSTALLED NEW FLOORBOARD IAW AMM 53-10-25-04-02 AND IAW DWG SRZ-005.