What was found
NR 1 ENG PYLON BOTTOM LWR SURFACE 16" FWD OF AFT END, ATTACH WEB CRACKED 3EA PLACES AT PNEUMATIC PRESSURIZATION LINE MEASURED .4", .7", AND 1.0" IN LENGTHS. FOUND CRACKS ON WEB AT NR 1 PYLON BOTTOM LWR SURFACE 16" FWD OF AFT ENDTO BE OUT OF LIMITS IAW FSRM 54-54-11 AND SRM 51-72-10, PARA 1. R & R WEB ASSY IAW FSRM 51-72-10, PGS 1-3.