What was found
RT WING OTBD FIXED T/E RIB 26 TO RIB 29 HAS 3" AREA OF CORROSION AT 2ND FROM INBD END STATIC WICK BELOW BASE WITH 60 PERCENT WORKING FASTENERS AND DISBONDED EDGES ALONG ENTIRE LENGTH. R & R RT WING FIXED T/E WEDGE IAW FSRM 51-72-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING OTBD FIXED T/E RIB 26 TO RIB 29 HAS 3" AREA OF CORROSION AT 2ND FROM INBD END STATIC WICK BELOW BASE WITH 60 PERCENT WORKING FASTENERS AND DISBONDED EDGES ALONG ENTIRE LENGTH. R & R RT WING FIXED T/E WEDGE IAW FSRM 51-72-10.