What was found
DURING APPROACH, AT ABOUT 700 FT AGL, LEFT FWD ENTRY DOOR EICAS AND DISCRETE ENTRY LIGHTS ILLUMINATED. AFTER SHUTDOWN, THE LT FWD DOOR HANDLE WAS FOUND IN THE PARTIALLY OPEN POSITION. DOOR TORQUE FOR UNLATCHING INTERIOR DOOR HANDLE WAS BELOW MINIMUMS. ADUSTED L1 DOOR UNLATCHING TORQUE IAW AMM 52-11-00-206. OPS CHECKED L1 DOOR IAW AMM 52-11-00. ACFT RELEASED FOR SERVICE.