What was found
AFT CARGO BAY FRAME BS 1460 S23-24L UPPER FLANGE DENTED. R & R FRAME IAW SRM 51-40-02, FABRICATED NEW FRAME, LOCATED AND DRILLED IAW SRM 51-40-02 AND INSTALLED IAW SRM 51-40-02 AND DWG 146N1014. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY FRAME BS 1460 S23-24L UPPER FLANGE DENTED. R & R FRAME IAW SRM 51-40-02, FABRICATED NEW FRAME, LOCATED AND DRILLED IAW SRM 51-40-02 AND INSTALLED IAW SRM 51-40-02 AND DWG 146N1014. MAJOR REPAIR.