What was found
BS 365, BL 0 - RBL 62, FLOORBEAM UPPER TEE CORRODED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 DETAIL II & IV FIG 101. REMOVED AND REPAIRED UPPER CHORD AT STA 365 LBL 15.5 TO RBL 70 IAW SRM 53-00-51 FIG201, REPAIR 3. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 365, BL 0 - RBL 62, FLOORBEAM UPPER TEE CORRODED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 DETAIL II & IV FIG 101. REMOVED AND REPAIRED UPPER CHORD AT STA 365 LBL 15.5 TO RBL 70 IAW SRM 53-00-51 FIG201, REPAIR 3. MAJOR REPAIR.