What was found
CABIN, AT BS 1640 RBL 54 TO 45 FLOORBEAM HAS CORROSION. NEW FLOORBEAM INSTALLED IAW DWG 146N5089, SHT 1, REV B. REFER TO SNRM: N01086 FOR WORK DETAILS. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN, AT BS 1640 RBL 54 TO 45 FLOORBEAM HAS CORROSION. NEW FLOORBEAM INSTALLED IAW DWG 146N5089, SHT 1, REV B. REFER TO SNRM: N01086 FOR WORK DETAILS. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.