What was found
RIGHT WING INBD FLAP, OTBD AFT HINGE BRACKET PIVOT OTBD LUG BORE OTBD SPOT FACE FOUND CORRODED. REWORKED AND FOUND EXCEED LIMIT IAW CMM 57-52-03, REV 74. EXISTING THICKNESS: 0.263", MATERIAL REMOVED: 0.078", REMAINING THICKNESS: 0.185", MINIMUM THICKNESS: 0.205". REPAIR ACCOMPLISHED IAW EA 1-5750-162395 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 115.