What was found
FOUND CORROSION ON THE OUTER STRAP AT BS 1825 BETWEEN STR 2 -7 R. REPLACED WITH STRAP FABRICATED IAW DWG 148N3138, SHT 1, REV C AND INSTALLED IAW DWG 148N3105 SHT 1, REV C. REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON THE OUTER STRAP AT BS 1825 BETWEEN STR 2 -7 R. REPLACED WITH STRAP FABRICATED IAW DWG 148N3138, SHT 1, REV C AND INSTALLED IAW DWG 148N3105 SHT 1, REV C. REPAIR IS MAJOR.