What was found
TWELVE FASTENER HOLES FOUND CRACK INDICATION DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT RT WING LOWER SKIN ACCESS DOOR CUT-OUT BETWEEN STATION XORS= 690 AND STA XORS= 700. REPAIRED AS PER SRM 57-20-02 FIGURE 201 REPAIR 5 REVISION 51. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 115.