What was found
SEAT TRACK 1 BETWEEN FR 27 AND FR 28 TOP SURFACE CORROSION. AFTER CORROSION REMOVAL AREA IS OUT OF LIMITS. ORIG THICKNESS 0.078. THICKNESS AFTER REMOVAL 0.053. OUT OF LIMITS IAW SRM 53-10-16, PG 105, FIG A. REMOVED CORRSION FROM FLOOR STRUCTURE FR 27-FR 28 SEAT TRACK, NR 1 OTBD FLANGE TOP SURFACE IAW SRM 51-74-10 PAR 5A, PAGES 204-205. CHECKED LIMITS IAW SRM 53-10-16, PG 101, FIG 102, PG 105. FOUND AREAS TO BE OUT OF LIMITS. PERFORMED REPAIR TO AREA BETWEEN PRODUCTION SPLICE FR 26 TO FR 28 IAW SRM 53-10-16, PG 203-208, PAR 4.