What was found
BULK CARGO COMPARTMENT FR 70 CEILING PANEL PROFILE HAS FOUR AREAS OF CORROSION AT LOWER SURFACE DEFECT MEASURES FIVE SQUARE INCHES. AFTER REMOVAL OF LEVEL 1 CORROSION, FOUND THREE AREAS TO BE OUT OF LIMITS IAW SRM 51-73-11. REPAIRED 3 EA AREAS WITH FABRICATED DOUBLERS AND FILLERS IAW SRM 51-71-40, PB 201.