What was found
1.625" CRACK RT WING AT STATION XROS 1042. REMOVED AND TEMP INSTALLED TANK PLATE 639EB. REQUIRES HFEC SURFACE PROBE INSPECTION OF R/S CAP HORIZONTAL AND VERTICAL FLANGES FOR DISCONTINUITIES. REPORT TO ENGINEERING IF ANY FINDINGS. PERFORMED HFEC REF SIDM 20-30-00 OF RT R/S CAP TO IDENTIFY ENDS OF INDICATIONS. INDICATION RUNS HORIZONTALLY IN THE RADIUS OF THE CAP BETWEEN THE 2 LINES MARKED ON THE CAP NOTED IN THE PICTURE, ATTACHED TO ERS 13-00074. RT WING OTBD REAR LOWER SPAR CAP AT XORS 1044.9-1046.275 CRACK INTERIM REPAIR.