What was found
NR 2 ENG PYLON FWD ENG MOUNT FITTING, ALL 4 TENSIL BOLT HOLES AND SPOT FACES HAVE OXIDATION AT UPPER SURFACE. ALL TENSILE BOLT HOLES IN LIMITS AFTER OXIDATION REMOVAL IAW FSRM 54-51-81, 2 FIG, 104 SHT 2. BOTH INBD AND OTBD AFT SPOTFACES FOUND TO BE OUT OF LIMITS IAW SRM 54-51-81, CONFIG 2, FIG 104. COMPLIED WITH EA 6-5451-T0300079 REV NO POS P1.