What was found
RT WING - T/E LOWER ACCESS PANEL 641JB CUT-OUT FORWARD EDGE LOWER CAP, LOWER SURFACE FOUND CORROSION. CORROSION REMOVED AND REPROTECTED IAW SRM 51-21-01, REV 51. ORIGINAL THICKNESS: 0.120", MATERIAL REMOVED: 0.004", REMAINING THICKNESS: 0.0116" AND FOUND WITHIN LIMITS IAW SRM 57-00-00, FIG 202, REV 51. REPAIR CLASSIFIED AS MINOR IAW FEDEX GMM 6-2-100, REV 116.