What was found
MAIN DECK CARGO TRACK 3R HAS 2 INCH LONG DAMAGED AREA AT FR 74. FABRICATED, LOCATED, DRILLED, AND INSTALLED NEW SEAT TRACK SECTION 3R WITH SPLICES FROM FR73.5 TO 74.5 IN MDCC IAW SRM 51-72-10 PARA 6, SRM 51-40-21 PARA 6 & 8, AND SRM 53-10-16 PG 247-248. PROTECTED REPAIR IAW SRM 51-72-10 PARA 6 ITEM J.