What was found
12 EA FASTENER HOLES FOUND CRACK INDICATION DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT LT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 690 AND STA=700. REPAIRED AS PER SRM 57-20-02 REPAIR 5 FIGURE 201 REVISION 51. INITIAL REPEAT INSPECTION REQUIRED 2,000 CYCLES AFTER COMPLETION OF THIS REPAIR AND REPETITIVE INSPECTION EVERY 2,000 CYCLES AS PER SRM 57-20-02 TABLE 201 REPAIR 5 REVISION 51. REPAIR CLASSIFIED AS MAJOR PER GMM 6- 2-100 REVISION 116.