What was found
MAIN DECK LT CREASE BEAM WEB FOUND CORRODED BETWEEN BS 1080 AND 1100. R & R IAW DWG 144N5210, SHT 1, REV - AND INSTALLED IAW DWG 144N5200 SHT 1, REV B. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK LT CREASE BEAM WEB FOUND CORRODED BETWEEN BS 1080 AND 1100. R & R IAW DWG 144N5210, SHT 1, REV - AND INSTALLED IAW DWG 144N5200 SHT 1, REV B. MAJOR REPAIR.