What was found
CABIN FLOORBEAM HAS CORROSION BS 1661, RBL 55. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, PG. 104, DETAIL IV, SHEET 4 OF 4. R & R FLOORBEAM IAW DWG 146N5090. CAT "A" MAJOR REPAIR.