What was found
E/E BAY STRINGER SPLICE AT BS 435-445, S23R, FOUND CORRODED. REMOVED DAMAGE IAW SRM 51-10-02 ORIG MAT .063", AFTER REWORK .035", FOUND OUT OF LIMITS IAW SRM 53-00-03, PAGE 102, FIG 101, DETAIL 1 AND 11. REPLACED STRINGER SPLICE IAW SRM 51-40-02 CAT "A", MAJOR REPAIR.