What was found
AT STA 1140 LT SIDE CREASE BEAM HAS A CRACK THAT BROKEN IN TWO AT STATION 1140, LT SIDE, CREASEBEAM WAS CRACKED AT FASTENER HOLE, WHICH IS NOT ALLOWED IAW SRM 53-40-13, FIG. 101, NOTE "D", PAGE 102. R & R CREASEBEAM IAW SRM 51-40-02, DWG 144N5214, BS 1140, WL 208.10, CAT "A", CRACK IS 0.25". MAJOR REPAIR.