What was found
NR 2 SLAT HAS A CRACKED COVE PANEL AT INBD MAIN TRACK ATTACH AREA OSS 605 TO OSS 617. REMOVED DAMAGED PANEL, FABRICATED NEW, AND INSTALLED IAW DWG 114N4076 REV C & SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 SLAT HAS A CRACKED COVE PANEL AT INBD MAIN TRACK ATTACH AREA OSS 605 TO OSS 617. REMOVED DAMAGED PANEL, FABRICATED NEW, AND INSTALLED IAW DWG 114N4076 REV C & SRM 51-40-02.