What was found
FLAP RETRACTED PASSING 205KTS ECAM VMO WARNING O'SPD 205 KTS. ECAM CANCELED WARNING AND SLOWED TO 200 KTS. AFT T/O ECAM WRNG T/O CONF WRNG TOO LOW FLAPS ONLY MOMENTARYILY. PDIS 741 27-01 5155 AFT LANDING ECAM WARNING FWS AMBER FAULT MONITOR SYSTEM. AFTER TAKEOFF ECAM F/O TAT HEAT FAULT ADC NR 2 IND-MONITOR. FOUND FWC-2 LAST FLIGHT FAULT AND BOTH ADI'S HAD "CHECK ATT" FAULTS WITH IRU'S ALIGNED. PULLING THE C/B FOR FWC-2 REMOVED FAULT. REPLACED FWC-2 REF AMM 31-53-34-04 AND ECAM ADJ/TEST REF AMM 31-51-00-05-01 AND AFS LAND TEST REF AMM 22-40-00-5. OK FOR SERVICE.