What was found
FOUND L1 DOOR SLIDE IS NOT ARMING WHEN COMMANDED BY SLIDE ARM LEVER. FOUND BOLT MISSING IN GIRT BAR LINKAGE. INSTALLED BOLT FOR ACTUATING ARM FOR SLIDE ARMING INDICATION INTO BELLCRANK AND SECURED WITH ORIGINAL ATTACH NUT AND WASHER. INSTALLED IAW AMM 52-11-04-2 AND PERFORMED OPERATIONAL CHECK OF DOOR ARM AND INDICATION IAW AMM 52-11-00, SYSTEM OPS CHECKED NORMAL AND REINSTALLED SLIDE COVER IAW AMM 25-66-01.