What was found
BS 377.7, BL 0-RBL 24 FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. R & R FLOORBEAM, FABRICATED IAW DWG 141N5123, SHT 1, REV A AND INSTALLED IAW DWG 141N5113, SHT 1, REV F. REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 377.7, BL 0-RBL 24 FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. R & R FLOORBEAM, FABRICATED IAW DWG 141N5123, SHT 1, REV A AND INSTALLED IAW DWG 141N5113, SHT 1, REV F. REPAIR IS MAJOR.