What was found
BS 377.7, BL 0- RBL 54 FLOORBEAM UPPER TEE SURFACE FOUND CORRODED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5123, SHT.1 REV A AND INSTALLED IAW DWG141N5113, SHT 1, REV F. REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 377.7, BL 0- RBL 54 FLOORBEAM UPPER TEE SURFACE FOUND CORRODED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5123, SHT.1 REV A AND INSTALLED IAW DWG141N5113, SHT 1, REV F. REPAIR IS MAJOR.