What was found
BS 1661, BL 0-LBL 24, FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. FLOORBEAM FABRICATED IAW DWG 146N5110, SH 2 REV B AND INSTALLED IAW DWG 146N5090, SHT 5 REV- . REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1661, BL 0-LBL 24, FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. FLOORBEAM FABRICATED IAW DWG 146N5110, SH 2 REV B AND INSTALLED IAW DWG 146N5090, SHT 5 REV- . REPAIR IS MAJOR.