What was found
BS 1020-1040, RT CREASE BEAM WEB UPPER SURFACE FOUND CORRODED. R & R IAW DWG 144N5140, SHT 2, REV C. REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1020-1040, RT CREASE BEAM WEB UPPER SURFACE FOUND CORRODED. R & R IAW DWG 144N5140, SHT 2, REV C. REPAIR IS MAJOR.