What was found
RELAY K24051, THREE SOCKET BASE WIRES INSULATION COLOR CHANGED TO BROWNISH COLOR. RELAY K24051, SOCKET BASE AND WIRES W3135-0004-12, W3135-0005-12, W3135-0018-12, W3135-0012-12 AND W3240-0008-12. R & R IAW SWPM 30-30-11, 20-15-48, 20-15-46, 20-10-11 AND 20-10-12, REV 53.0. WIRING CONTINUITY CHECK IAW WDM 24-51-41, REV 15.0 FOUND SATISFACTORY. DC STANDBY POWER AND AC EXTERNAL POWER OPS TEST CARRIED OUT IAW AMM 24-30-00-5 AND 24-41-00-5, REV 67.2. ENGINE IDLE RUN PERFORMED IAW JRH REV 3.0 AND APU START CHECK CARRIED OUT IAW AMM 49-11-00 REV 67.2 FOUND SATISFACTORY. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 REV 116.