What was found
EIGHT FASTENER HOLES FOUND TO HAVE CRACK INDICATIONS, FOUND DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT RIGHT WING LOWER SKIN ACCESS DOOR CUT-OUT BETWEEN STATIONS XORS 683.4 AND XORS 713.6. REPAIRED IAW SRM 57-20-02, REPAIR 5 FIG 201, REV 52. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 116.