What was found
FR 13 CIRCUMFERENTIAL JOINT NDT HOLE DAMAGE INDICATION LOCATED AT X 5 FASTENERS (MARKED IN BLACK INK) ABOVE STR 25RH X 5 FASTENERS LOCATED ON FR 13, STR 25RH. CLEANED, DE-BURRED AND HFEC INSPECTION C/OUT. NO FAULT INDICATIONS APPARENT. FASTENERS REPLACED WHILST ACCOMPLISHING EA 6-5300-167481 AND NRC N00518.