What was found
LIGHTNING STRIKE ON FUSELAGE SKIN BS 585 BETWEEN S29 - 30L. BLENDED OUT AREA AND FOUND AREA CRACKED. CUTOUT DAMAGED AREA AND FABRICATED REPAIR DOUBLER AND FABRICATED FILLER. INSTALLED REPAIR IAW SRM 53-00-01, NDTM PT6 51-00-10, NDTM PT6 51-00-19, SRM 53-00-01, FIG 201, REPAIR 15, SRM 51-20-01 AND SRM 51-40-02.