What was found
NOSE LANDING GEAR WHEEL WELL RT TRUNNION FITTING LOWER AREA FOUND CRACKED. AREA TRIMMED OUT AND REPAIRED IAW SRM 53-10-14, FIG 202. REPAIR 2, REV 53. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 116. INITIAL INSP AT 1500 CYCLES AND REPETITIVE INSP REQUIRED AT 1500 CYCLES USING HIGH FREQUENCY EDDY CURRENT OR LIQUID PENETRANT METHOD IAW SRM 53-10-14, TABLE 201, FIG 202, REPAIR 2, REVISION 53.