What was found
DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION, FOUND ONE CRACK INDICATION ON NR 7 MAIN DECK CARGO DOOR LOWER FRAME FITTING AT HOLE "A". SUPPORT FITTING R & R IAW SRM 51-31-01, REV 53. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 116.