What was found
RIGHT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN XORS 683.4 AND XORS 713.6, TEN FASTENER HOLES FOUND CRACKED INDICATION DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION. CARRIED OUT BUSHING REPAIR IAW SRM 57-20-02, REPAIR 5, FIG 201 REV 53 AND EA 1-5710-T0301691 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 116.