What was found
LEFT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN XORS 683.4 AND XORS 713.6, SEVEN FASTENER HOLES FOUND CRACKED INDICATION DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION. CARRIED OUT BUSHING REPAIR IAW SRM 57-20-02, REPAIR 5, FIGURE 201, REV 53 AND EA 1-5710-T0301690, PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 116.