What was found
BULK CARGO DOOR SILL FOUND CORROSION SURROUNDING FASTENER HOLES BETWEEN FR 68 & 69. REPLACED SILL IAW SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK CARGO DOOR SILL FOUND CORROSION SURROUNDING FASTENER HOLES BETWEEN FR 68 & 69. REPLACED SILL IAW SRM 51-40-21.