What was found
MAIN DECK LBL58 INBD CREASE BEAM IS CORRODED STA 755 CORRODED AREA DIMENSIONS L= 1.30", W=1.00" MAX, DEPTH= 0.010", FOUND TO BE OUT OF LIMITS IAW SRM 53-30-13, FIG 101, DETAIL 8, PG.105. REPLACED DAMAGED CHORD FOR A NEW ONE, FABRICATED, IAW SRM,53-30-10 FIG 1 DETAIL 3 AND DWG 143N5520, SH 4,5 AND PL SH 16, FROM STA 755 TO STA 900, LBL 58, IAW SRM 51-40-02 AND DWG 143N5520, SH 4 & 5. MAJOR REPAIR (CAT "A")