What was found
NR 2 ENGINE GENERATOR FAULTED DURING CLIMBOUT AT ABOUT 4500 FT. ATTEMPTED RESET IAW ECAM. DRAINED NR 2 IDG OIL, INSTALLED NEW IDG OIL FILTER, RAN ENGINE NR 2 GENERATOR. OPS CHECKED GOOD. IAW MM 24-11-00-03-01, & MM 12-13-24-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENGINE GENERATOR FAULTED DURING CLIMBOUT AT ABOUT 4500 FT. ATTEMPTED RESET IAW ECAM. DRAINED NR 2 IDG OIL, INSTALLED NEW IDG OIL FILTER, RAN ENGINE NR 2 GENERATOR. OPS CHECKED GOOD. IAW MM 24-11-00-03-01, & MM 12-13-24-00-01.