What was found
L1 DOOR SILL, CREASEBEAM STA 330-380, WL 208, CORRODED. FOUND OUT OF LIMITS IAW SRM 51-10-02 STEP 15 AND SRM 53-10-08 FIG 101 DET IX. REMOVED AND REPLACED WITH NEW CREASE BEAM ANGLE IAW DWG 657N3381 AND SRM 51-40-02. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L1 DOOR SILL, CREASEBEAM STA 330-380, WL 208, CORRODED. FOUND OUT OF LIMITS IAW SRM 51-10-02 STEP 15 AND SRM 53-10-08 FIG 101 DET IX. REMOVED AND REPLACED WITH NEW CREASE BEAM ANGLE IAW DWG 657N3381 AND SRM 51-40-02. MAJOR REPAIR.