What was found
BS 740 -752, R2 DOOR LOWER SILL WEB FOUND CORRODED AT LOWER SURFACE, AROUND FASTENER HOLES. CORROSION REMOVED AS PER SRM 51-10-02 REV 109. MATERIAL REMOVED 0.012" FOUND EXCEED LIMIT AS PER SRM 53-30-15 ALLOWABLE DAMAGE 1 FIG. 101 REV. 109. DOOR LOWER SILL WEB REMOVED AND REPLACED AS PER SRM 51-40-02 REV. 109 AND DWG 143N8322 SH 1 REV. K WITH FABRICATED WEB. NEW DOOR LOWER SEAL WEB FABRICATED AS PER DWG 143N8322 SH 1 REV K. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.