What was found
L2 DOOR SLIDE REMOTE PRESSURE INDICATIOR PTT SWITCH FAILED TO TEST. REPLACED BATTERIES. REMOTE PRESSURE INDICATOR EVAC SLIDE TESTED NORMAL IAW MM 21-61-04-5. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L2 DOOR SLIDE REMOTE PRESSURE INDICATIOR PTT SWITCH FAILED TO TEST. REPLACED BATTERIES. REMOTE PRESSURE INDICATOR EVAC SLIDE TESTED NORMAL IAW MM 21-61-04-5. OK FOR SERVICE.