What was found
THREE CRACKS WERE FOUND AT LT INNER LONGITUDINAL BEAM FLANGE STR 11 BETWEEN FRAMES 73A AND 74A. CUT OUT DAMAGE PORTION OF BEAM AND REWORK MILLED STEP. INSTALL THE REPAIR ANGLE AND FILLER IAW SRM 53-18-18, FIG 205A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THREE CRACKS WERE FOUND AT LT INNER LONGITUDINAL BEAM FLANGE STR 11 BETWEEN FRAMES 73A AND 74A. CUT OUT DAMAGE PORTION OF BEAM AND REWORK MILLED STEP. INSTALL THE REPAIR ANGLE AND FILLER IAW SRM 53-18-18, FIG 205A.