What was found
AFT PIT BETWEEN BS 1280 - BS 1300, STRINGER 28R, CORROSION ON STRINGER. REMOVED CORROSION ON AFT PIT STRINGER, BETWEEN BS 1280 - BS 1300, STRINGER 28R IAW SRM 51- 10-02. CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03, FIG 201, DETAIL 2. REMOVED DAMAGE & REPAIRED STRINGER IAW SRM 53-00-03, FIG 201, DETAIL 2, REPAIR 2.