What was found
FWD PIT, BS 680 STRINGER 23L - STRINGER 24L, FRAME INBD FLANGE DENTED. CHECK LIMITS IAW-SRM-53-00-07 FIG 101 SHEET 1 PG 100, FOUND OUT OF LIMITS, REMOVED FRAME IAW-SRM-51-40-02, RECEIVED NEW FRAME, LOCATED AND DRILLED IAW-SRM-51-40-05, INSTALLED FRAME IAW-DWG 143N1024 AND SRM-51-40-02, REF DWG 143N1013, CAT "A" MAJOR REPAIR