What was found
PDIS 933 73-10 0004481 28NOV13 RSW CLOSE LOG PAGES 02099057. NORMAL START LT ENG. DURING RT ENG START, THE LT ENG FAILED. FUEL FLOW WAS ZERO, EICAS MESSAGE LT ENG FUEL VLV. FACT 28NOV13 04:00 RSW R PERFORMED TEST ON NR 1 ENG FUEL VLV SYS IAW MM 28-22-11-5. PULLED & RESET NR 1 ENG FIRE HANDLE. RAN NR 1 ENG IAW B757 JRH FOR 8 MINUTES, ALL ENG PARAMETERS INDICATED NORMAL, OK FOR SERVICE.