As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK AT STATION 333.45, FLOOR BEAM UPPER CHORD CORRODED. REMOVED CORROSION IAW SRM 51-10-02. CHECK LIMITS ORIGINAL THICK .135 MATERIAL LOST .027 MATERIAL REMAINING .108 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL VI. REMOVED AND INSTALLED NEW FLOOR SUPPORT BEAM SHORT ON STA 333.45 LT IAW SRM 51-40-02 AND DWG NR 1415110-1. CAT "A" MAJOR REPAIR