What was found
CABIN FLOOR RT OTBD CREASE BEAM HAS CORROSION. CHAFF MARKS STATION 1400 - 1630, STRINGER 17R. BLENDED CORROSION & CHAFE MARKS ON CREASE BEAM LOCATED AT RT OTBD STATION 1400 - 1630 IAW 757-200 SRM 51-10-02 PG 16 FIG 1. FOUND TO BE OUT OF LIMITS IAW 757-200 SRM 53-60-13 PG 105 FIG 101. REMOVED .008 FROM ORIGINAL THICKNESS OF .070. REPLACED CREASE BEAM IAW DN146N5590.